<LOGO>
FM Transmitter Measurement Report
Created: 2025-06-26 12-52-03
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 51 dBuV SANDELS
Pilot RDS Phase Difference
6.1 kHz 5.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
13 kHz 19 kHz 10266 0,0195
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,1 dBr 2,77 dBr 4,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 19 kHz MIN: 13 kHz % above 76 kHz: 0,0195 Acquired: 2025/06/26 12.50.59 Total samples: 10266 Equivalent time: 0:08:33 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 4,8 dBr MIN: 1,1 dBr AVE: 2,77 dBr % above 12,2 dBr: 0,0 Last value: 1,5 dBr (2025/06/26 12.50.59) 12.38 12.40 12.42 12.44 12.46 12.48 12.50 0 2 4 Pm [dBr]